MiCOM P13x Protection & Control Relays

Protection that reacts before damage begins

MiCOM P13x delivers fast, selective overcurrent and earth-fault protection for feeders, motors, and industrial networks — engineered for dependable tripping in even the harshest grid conditions.

Explore More

Slow relays don’t just delay protection — they risk everything

Aging protection struggles with evolving loads, harmonics, and fault levels. One delayed trip can lead to equipment burnouts, outages, and costly downtime across the network.

Slow trip response

Hidden grid faults

Unreliable coordination schemes

Complex field setup

Zero cyber readiness

Meet MiCOM P13x — dependable, digital feeder protection

A robust overcurrent and earth-fault relay platform designed for feeders, motors, and transformers in utilities and industries. P13x combines fast fault detection, flexible protection curves, and modern communication protocols — built to keep medium-voltage networks stable and safe.

Meet MiCOM P13x — dependable, digital feeder protection
Meet MiCOM P13x — dependable, digital feeder protection
Meet MiCOM P13x — dependable, digital feeder protection
Meet MiCOM P13x — dependable, digital feeder protection
Meet MiCOM P13x — dependable, digital feeder protection
Meet MiCOM P13x — dependable, digital feeder protection

Fast, flexible, and field-proven protection

From precise tripping to wide configuration options, P13x keeps critical feeders protected without complexity

Fast fault clearance

High-speed detection for phase, earth, and neutral faults

Protection your way

Supports IDMT, DTOC, user curves, directional settings, and multi-stage protection.

Wide communication compatibility

Works seamlessly with Modbus, IEC 60870-5-103, DNP3, and IEC 61850 (model-dependent)

Built for harsh grids

Handles CT saturation, harmonics, and network instability with strong stabilizing logic.

Flexible I/O

Modular inputs/outputs allow easy adaptation to any scheme upgrade.

Simple to configure

Front-panel navigation and software tools make setup fast and intuitive

Engineered for accuracy and stability

Every input, output, and protection stage built to withstand real-world grid conditions.

Engineered for accuracy and stability
Engineered for accuracy and stability

Current Inputs: 1 A / 5 A

Voltage Inputs: Optional VTs depending on model

Protection: Phase/earth overcurrent, directional, thermal, sensitive earth fault

Binary I/O: Flexible mapping and configurable logic

Communication: Modbus, IEC-103, IEC 61850 (variant-based), DNP3

Aux Supply: 24–250 V DC / 100–230 V AC

Operating Temperature: –25 °C to +55 °C

Mounting: Flush / Surface with modular hardware options

Compliance: IEC/EN 60255 series

Where MiCOM P13x fits perfectly

Reliable protection for feeders, motors, substations, and industrial networks.

Feeder overcurrent protection

Motor and transformer backup protection

Industrial and utility substations

Ring and radial distribution networks

Industrial plants (steel, water, chemicals, F&B)

Trusted across industries that can’t afford weak protection.

Built for dependable operation across demanding electrical environments.

Utilities & Distribution Networks

Utilities & Distribution Networks

Utilities & Distribution Networks

Oil, Gas & Chemicals

Manufacturing & Metals

Water & Wastewater

Commercial & Infrastructure

Protection tuning that leaves nothing to chance

From testing to logic configuration, we optimize P13x performance for your system.

Services
Relay Testing, Programming & Configuration

Relay Testing, Programming & Configuration

Complementary Protection Solutions

Compatible relays, communication modules, and system components that enhance feeder protection schemes and support coordinated network protection.

Upgrade your feeder protection today

Talk to our experts to select, configure, or retrofit the right MiCOM P13x for your network.

Get A Quote
Get A Quote
0 Enquiry List