Distance Protection Relay for MiCOM P436 & P438 Catenary Systems

Railway catenary protection that you can count on

MiCOM P436 and P438 deliver high-speed distance, overcurrent, and voltage protection for railway feeders — engineered for 16.7 Hz and 25/50/60 Hz networks that demand precision, stability, and absolute reliability.

Explore More

On rail power, mistakes travel fast

A single delay in tripping can cut traction supply, stall trains, and overload upstream substations. Legacy relays struggle with fast faults, long feeder lengths, multi-frequency grids, and complex switching logic — risking safety and uptime across the entire line.

Slow fault isolation

Weak distance coverage

Unsafe switchgear control

No railway-frequency support

Poor feeder visibility

Meet MiCOM P436 & P438 — built for catenary protection

P436 and P438 are digital distance and overcurrent protection relays for railway catenary feeders. P436 covers 16.7 Hz networks. P438 handles 25/50/60 Hz systems. Both deliver fast fault detection, advanced interlocking, bay control, disturbance recording, and deep diagnostics — all in modular Px3x hardware built to thrive in demanding traction substations.

Meet MiCOM P436 & P438 — built for catenary protection
Meet MiCOM P436 & P438 — built for catenary protection
Meet MiCOM P436 & P438 — built for catenary protection
Meet MiCOM P436 & P438 — built for catenary protection
Meet MiCOM P436 & P438 — built for catenary protection
Meet MiCOM P436 & P438 — built for catenary protection
Meet MiCOM P436 & P438 — built for catenary protection
Meet MiCOM P436 & P438 — built for catenary protection

Protection engineered for traction grids

Distance precision. Overcurrent speed. This is railway performance you can count on.

Accurate multi-zone distance protection

Four zones with forward/reverse reach, startup detection, and wrong-phase protection

Fast, selective overcurrent defense

DTOC, IDMT, high-set, and directional elements tuned for rail feeders.

Stronger switching safety

Full bay interlocking with checks for unsafe operations.

Simplified bay control

Operate breakers, isolators, and earthing switches directly from the relay.

Thermal and voltage stability

Over/under-voltage, frequency, thermal, and SOTF protection.

Railway defrost compatibility

Supports defrost differential schemes for catenary de-icing.

Event-rich diagnostics

Fault records, oscillography, overload logs, and condition monitoring.

Built for fast, frequency-specific protection

Modular Px3x hardware — tuned for traction reliability.

Built for fast, frequency-specific protection
Built for fast, frequency-specific protection

16.7 Hz (P436) / 25–60 Hz (P438)

4-zone distance protection

High-impedance Delta-I element

DTOC/IDMT overcurrent stages

Over/undervoltage (27/59), frequency (81)

Thermal overload (49)

Auto-reclose (79), synchronism check (25)

SOTF, CBF, CB supervision

Defrost differential measurement

3 CT + 2 VT inputs

Up to 56 binary inputs

Up to 44 binary outputs (incl. high-break)

Optional PT100 & analog I/O

Graphic or text LCD, configurable LEDs

IEC 61850, Modbus, DNP3, 103/101

GOOSE + InterMiCOM for fast signalling

Ethernet options: RJ45, LC SFP, redundancy (PRP/HSR/RSTP)

Event, disturbance, and oscillography logs

Auxiliary supply: 24–60 V DC or 60–250 V DC / 100–230 V AC

Operating range: –25°C to +55°C

Mounting: 40TE / 84TE cases

Where P436 & P438 fit perfectly

Purpose-built for catenary feeders and traction substations.

Railway traction and auxiliary substations

Catenary feeder protection

Dead-tank transformer zones

Autotransformer-fed line protection

Railway busbar voltage monitoring

Critical traction supply systems

Shaped for rail. Trusted across grids

Ideal for traction networks, resilient for utilities and industrial feeders.

Railways & metros

Railways & metros

Railways & metros

Transport infrastructure

Utility substations

Industrial distribution networks

Traction auxiliary systems

Catenary Protection Coverage

Designed for railway feeders, traction substations, dead-tank transformer zones, and autotransformer-fed lines requiring fast, selective distance protection.

Services
Relay Testing, Programming & Configuration

Relay Testing, Programming & Configuration

Complementary Traction Protection Solutions

Compatible relays, communication modules, and bay-control components that strengthen coordinated protection and safe operation across railway power systems

Upgrade your catenary protection

Talk to our experts for configuration, setup, or relay modernisation

Get A Quote
Get A Quote
0 Enquiry List