MiCOM P64x transformer protection relay. Relay maintenance and protection relay commissioning services for selective, high-speed, and reliable fault coverage.

Transformer protection that thinks faster than faults

MiCOM P64x delivers high-speed differential, REF, thermal, and overfluxing protection — built for two-winding, three-winding and autotransformer zones where precision is everything.

Explore More

A transformer fault doesn’t wait. Your protection shouldn’t either

Older relays misjudge inrush, ignore negative-sequence stress, miss early earth faults and fail to restrain during overfluxing. That means false trips, long outages and transformers pushed beyond safe limits.

Slow fault isolation

Poor inrush restraint

Weak earth-fault sensitivity

No overfluxing defense

Limited event insights

Meet MiCOM P64x — transformer-grade protection, perfected

The MiCOM P64x family (P642 / P643 / P645) brings phase-segregated differential protection with transformer-specific logic for stable, selective and fast response. It covers REF, thermal, overfluxing, directional overcurrent, negative sequence, voltage and frequency — all backed by programmable logic, deep recording and SCADA-ready communication. With flexible I/O, Ethernet options, fiber links, and optional process-bus integration, P64x fits simple two-winding units and complex EHV autotransformers alike.

Meet MiCOM P64x — transformer-grade protection, perfected
Meet MiCOM P64x — transformer-grade protection, perfected
Meet MiCOM P64x — transformer-grade protection, perfected
Meet MiCOM P64x — transformer-grade protection, perfected
Meet MiCOM P64x — transformer-grade protection, perfected
Meet MiCOM P64x — transformer-grade protection, perfected

Protection tuned to transformer behaviour

From overfluxing to winding faults, P64x adapts to real transformer physics.

High-speed differential logic

Phase-segregated, secure, and stable even during inrush and CT saturation.

REF that sees the smallest faults

Low- and high-impedance options detect internal earth faults early.

Thermal expertise built in

IEEE-based thermal modelling protects winding hot-spots and top-oil.

Overfluxing control that saves cores

Multi-stage V/Hz protection keeps magnetic stress in check.

Directional overcurrent backup

Four fully configurable stages for internal and external faults.

Smart supervision everywhere

VT/CT monitoring, breaker failure, negative sequence and deep diagnostics.

Engineered for accuracy, stability and endurance

Hardware flexibility with transformer-centric performance.

Engineered for accuracy, stability and endurance
Engineered for accuracy, stability and endurance

Up to 16 digital inputs

Up to 24 outputs with high-break options

CT inputs 1A / 5A

Transformer REF inputs (low & high Z)

RTD inputs for up to 10 PT100 sensors

Differential protection

REF (low and high impedance)

Overcurrent IDMT / DT

Negative phase sequence

Thermal overload

Overfluxing (VHz)

Under/over-voltage

Under/over-frequency

Breaker failure

VT/CT supervision

PSL logic

RS232 front port

RS485 / K-bus rear

Fiber optic links

IEC 61850 Ethernet

DNP3 / MODBUS / IEC 60870-5-103

IEC 61850-9-2LE process bus (optional)

IRIG-B time sync

–25°C to +55°C

IP52 front

Wide-range auxiliary supply (24–250 VDC / 100–240 VAC)

45–65 Hz frequency capability

IEC 60255 tested

Where MiCOM P64x delivers clarity

Protection that fits every transformer topology.

Two-winding transformers

Three-winding transformers

Autotransformers

EHV and HV transformer bays

Ring bus and mesh bus stations

Industrial and utility substations

Made for transformers. Built for critical networks

Ideal for high-duty networks with continuous load and complex switching.

Transmission utilities

Transmission utilities

Transmission utilities

Distribution networks

Heavy industries

Refineries & process plants

Generation switchyards

Transformer protection set exactly right

We configure, test and verify P64x settings for every winding, tap and fault scenario.

Supporting systems for complete transformer schemes

A compatible range of protection, monitoring, and communication products that work alongside MiCOM P64x to deliver coordinated backup protection, seamless SCADA integration, and long-term operational reliability.

Upgrade your transformer protection

Talk to our relay specialists to deploy or modernise your protection with MiCOM P64x.