Feeder Management Relay for MiCOM P14x Feeder Protection

Feeder protection that reacts before trouble shows

MiCOM P14x delivers fast, flexible overcurrent and earth-fault protection for overhead lines and cables — built for every grounding system, every voltage class, and every feeder scheme.

Explore More

On feeders, hesitation costs more than faults

Aging relays miss direction, struggle with compensated networks, mis-handle cold load pickup and can’t keep up with today’s mixed overhead–underground grids. The result? Mis-coordination, wrong-way trips and expensive interruptions across the network.

Weak directional logic

No SEF sensitivity

Slow cold-load handling

Inaccurate voltage restraint

Poor event insight

Meet MiCOM P14x — feeder control done right.

The MiCOM P14x family (P141–P145) is a powerful feeder protection platform for MV and HV lines. It brings multi-stage, fully directional phase and earth-fault protection, high-sensitivity SEF, REF capability, negative-sequence elements and an extensive voltage/frequency suite. With flexible I/O, advanced logic, deep recording and optional bay control in P145, the P14x adapts to every feeder type, grounding practice and grid condition.

Meet MiCOM P14x — feeder control done right.
Meet MiCOM P14x — feeder control done right.
Meet MiCOM P14x — feeder control done right.
Meet MiCOM P14x — feeder control done right.
Meet MiCOM P14x — feeder control done right.
Meet MiCOM P14x — feeder control done right.
Meet MiCOM P14x — feeder control done right.

Protection that follows every contour of your feeder

Direction, sensitivity and stability — engineered for complex line behaviour.

Six-stage phase protection

Directional or non-directional. IDMT or definite-time. Fully shapeable for any grading plan.

Three-layer earth-fault logic

Derived, measured and SEF — each with four stages for precision on every network type.

Voltage-dependent awareness

Voltage-controlled and voltage-restrained overcurrent boosts reach on distant faults, safely.

REF for internal sensitivity

High- or low-impedance REF detects hidden earth faults missed by standard EF.

Negative-sequence intelligence

Detects unbalanced faults fast, even before current rises fully.

Thermal and overload security

Cable, transformer and conductor protection with realistic thermal models.

Smarter feeder behaviour

Cold load pickup, blocked OC logic and selective OC logic for accurate switching.

Built for speed. Tuned for selectivity

Multi-stage logic, modular hardware and deep diagnostics.

Built for speed. Tuned for selectivity
Built for speed. Tuned for selectivity

1A/5A CT inputs

VT inputs 100–120 V or 380–480 V (variant-dependent)

8–32 logic inputs

7–32 output relays

High-break options for DC tripping

Optional analog inputs/outputs

6-stage phase overcurrent (50/51/67)

4-stage earth-fault + SEF (50N/51N/67N/67W)

Voltage-dependent OC (51V)

REF (64)

Negative-sequence OC (46)

Broken conductor detection (46BC)

Thermal overload (49)

Over/under-voltage (27/59)

Over/under-frequency + df/dt (81)

Power protection (32)

dv/dt

Cold load pickup

Auto-reclose (79) — P142, P143, P145

Check sync (25) — P143, P145

IEC 61850 Ed.1/Ed.2

K-Bus / RS-485 / Fibre

IEC 60870-5-103/101

Modbus / DNP3 / Courier

Redundant Ethernet (PRP/HSR)

InterMiCOM (optional)

IRIG-B time sync

–25°C to +55°C

IP52 front

40/60/80 TE case options

IEC 60255 EMC/thermal/vibration compliance

Where MiCOM P14x makes the difference

Flexible enough for every feeder — overhead, underground or hybrid.

Overhead line protection

Underground cable protection

Mixed line/cable feeders

Solid, impedance, isolated and Petersen coil networks

Distribution and transmission feeders

Industrial and utility radial or ring networks

Purpose-built for feeders. Trusted across grids

The P14x fits anywhere lines need accurate direction and fast clearing.

Utilities & DISCOMs

Utilities & DISCOMs

Utilities & DISCOMs

Transmission operators

Industrial distribution networks

Transport and infrastructure power

Oil, gas & process plants

Feeder protection, engineered to perform

We configure, test, integrate and retrofit every P14x to match your protection philosophy.

Services
Relay Testing, Programming & Configuration

Relay Testing, Programming & Configuration

Integrated systems for complete feeder protection

Compatible protection, control, and communication solutions designed to work alongside MiCOM P14x, enabling coordinated protection, seamless automation, and reliable feeder management across utility and industrial networks.

Upgrade your feeder reliability

Talk to our protection experts to modernise or configure your network with MiCOM P14x.

Get A Quote
Get A Quote