Interconnection Protection Relay for MiCOM P341

Interconnection protection that never second-guesses

MiCOM P341 secures tie-lines, interconnections, and critical network boundaries with fast distance protection, deep overcurrent logic, and precision frequency monitoring — built for grids where one unstable moment can ripple across regions.

Explore More

At grid edges, hesitation becomes instability

Old relays miss swings, misjudge intertie conditions, lag on breaker failures, and can’t keep up with modern synchronism and frequency behavior. One wrong trip at the boundary — and the whole grid feels it.

Slow fault detection

Weak swing stability

Poor breaker oversight

Limited frequency logic

No redundancy paths

Meet MiCOM P341 — interconnection-grade protection with absolute authority

The P341 brings proven distance protection, multi-stage overcurrent logic, frequency-based schemes, and robust breaker supervision into one modular relay. Optimised for interconnections, tie-lines, busbars, feeders, and transformers, it blends multi-zone distance protection, PSL automation, wide-frequency protections, and thermal dynamic line rating. Built for modern substations where stability, communication, and cyber security matter most.

Meet MiCOM P341 — interconnection-grade protection with absolute authority
Meet MiCOM P341 — interconnection-grade protection with absolute authority
Meet MiCOM P341 — interconnection-grade protection with absolute authority
Meet MiCOM P341 — interconnection-grade protection with absolute authority
Meet MiCOM P341 — interconnection-grade protection with absolute authority
Meet MiCOM P341 — interconnection-grade protection with absolute authority
Meet MiCOM P341 — interconnection-grade protection with absolute authority

Protection tuned for how interconnections behave

From distance faults to frequency events — every boundary risk handled.

Fast distance protection

Multi-zone distance elements with adaptive characteristics for precise fault clearing.

Stronger backup layers

Phase, earth, sensitive earth, and restricted earth fault stages with inverse and definite-time curves.

Swing and stability intelligence

Power swing blocking, out-of-step tripping, and vector-shift detection for stable operation.

Frequency-aware protection

ROCOF, under/over-frequency, and voltage-vector shift for reliable intertie management.

Breaker reliability built-in

Breaker failure, condition monitoring, and trip-circuit supervision ensure dependable clearing.

Flexible scheme logic

PSL for intertripping, permissive schemes, interlocking, and custom network logic.

Deep line visibility

Dynamic line rating, SOE, fault logs, disturbance waveforms, and thermal monitoring for informed operation.

Built for precision. Proven on demanding networks

Every module is designed for protection-critical performance.

Built for precision. Proven on demanding networks
Built for precision. Proven on demanding networks

Up to 32 binary inputs

Up to 32 outputs (configurable)

Analog/RTD inputs via expansion boards

1A / 5A CT support

Voltage inputs for tie-line sensing

Multi-zone distance protection

Phase & earth overcurrent

Sensitive + restricted EF

Thermal overload

Vector shift & ROCOF

Breaker failure (50BF)

SOTF, autoreclose

Intertripping, permissive schemes via PSL

SOE, waveform & disturbance recording

IEC 61850 Ed.1/Ed.2 with GOOSE

Modbus / Courier / DNP3

IEC 60870-5-103

RS485 serial / fibre

Ethernet with PRP/HSR options

Time sync: IRIG-B

–25°C to +70°C

IP52 front

Altitude up to 2000m

IEC 60255-tested

Where MiCOM P341 leads

Any interconnection. Any tie-line. Any complex protection boundary.

Interconnection protection

Transmission & distribution tie-lines

Busbar and feeder intertie schemes

Transformer backup protection

Industrial and utility boundary points

Grids requiring swing-checked, frequency-aware protection

Engineered for grid interconnections. Ready for every network type

Perfect for high-value, high-impact points across power and industry.

Utilities and transmission operators

Utilities and transmission operators

Utilities and transmission operators

Grid substations

Industrial networks with tie-feeds

Independent power producers

Hybrid and renewable grids

Critical substation intertie nodes

Interconnection protection tuned to your network logic

From distance settings to swing curves — we configure P341 the way your grid runs.

Services
Relay Testing, Programming & Configuration

Relay Testing, Programming & Configuration

Integrated solutions for intertie protection schemes

Complementary protection, control, and communication equipment engineered to operate alongside MiCOM P341, enabling coordinated distance schemes, reliable breaker supervision, and secure substation automation across interconnected networks.

Upgrade your interconnection protection

Speak to our engineers to configure, modernise or retrofit MiCOM P341 into your substation.

Get A Quote