Generator Protection Relay for MiCOM P34x

Generator protection that never hesitates

MiCOM P34x secures generators and generator-transformer units with fast differential protection, deep backup logic and precise synchronism control — built for plants where a single mis-trip can cost megawatts.

Explore More

In generation, one wrong second can drop the grid

Legacy relays struggle with inrush, miss internal faults, lag on breaker failures, and lack synchronism logic for modern generator bays. A slowdown becomes an outage. An outage becomes a cascade.

Slow internal-fault clearing

Weak synchronism control

No redundancy options

Poor breaker supervision

Limited plant visibility

Meet MiCOM P34x — generator-grade protection with total control

The MiCOM P34x family (P342 / P343 / P344 / P345 / P391) brings hardened differential protection, synchronism checks and complete scheme logic into one modular platform. Optimised for generators, GT units and complex plant bays, it blends fast 87G protection, multi-stage backup, advanced logic and rich recording. Designed for modern substations where reliability, selectivity and communication matter.

Meet MiCOM P34x — generator-grade protection with total control
Meet MiCOM P34x — generator-grade protection with total control
Meet MiCOM P34x — generator-grade protection with total control
Meet MiCOM P34x — generator-grade protection with total control
Meet MiCOM P34x — generator-grade protection with total control
Meet MiCOM P34x — generator-grade protection with total control

Protection built around how generators behave

From internal faults to synchronism checks — every risk handled.

Instant internal-fault detection

Biased differential 87G with inrush and overfluxing restraint.

Multi-layer backup protection

Phase, earth-fault, neutral and sensitive EF with directional options.

Stability under every condition

Voltage, frequency and thermal monitoring that reacts before limits break.

Breaker health assurance

Breaker failure, condition supervision and trip-circuit logic built in.

Flexible scheme logic

PSL for interlocking, intertripping and plant-specific sequences.

Smarter synchronism

Advanced check-sync for safe, seamless breaker closing.

Deep event visibility

Waveforms, SOE, fault locator and detailed records for quicker restoration.

Built for precision. Proven in harsh plant environments

Every module meets generator-grade performance standards.

Built for precision. Proven in harsh plant environments
Built for precision. Proven in harsh plant environments

Up to 32 binary inputs

Up to 32 outputs

High-break output options for heavy DC loads

RTD/analog inputs via CLIO board

1A / 5A CT inputs

Voltage inputs for generator and system sensing

87G biased differential

Overcurrent & earth-fault (multi-stage)

Sensitive EF / neutral EF

Thermal overload (49)

Voltage & frequency suite

Check synchronization (25)

Breaker failure (50BF)

Intertripping & interlocking via PSL

Sequence of events & waveform recording

IEC 61850 Ed.1/Ed.2

Modbus / Courier / DNP3

IEC 60870-5-103

Serial RS485 / fibre

Ethernet & redundant Ethernet (PRP/HSR/RSTP)

IRIG-B time sync

InterMiCOM teleportation

–25°C to +55°C

IP52 front

40 / 80 TE case options

IEC 60255 tested

Where MiCOM P34x leads

Any generator. Any topology. Any critical plant configuration.

Generator protection

Generator-transformer (GT) units

Industrial captive power units

Hydro, thermal and gas plants

Complex station and bay schemes

Plants requiring synchronism-checked switching

Engineered for generation. Ready for every grid

Perfect for high-value generating assets across power and industry

Power generation plants

Power generation plants

Power generation plants

Captive power & industrial utilities

Independent power producers

Grid substations

Renewables with synchronous generators

Critical industrial generation processes

Generator protection fine-tuned to plant logic

From 87G testing to synchronism settings — we configure and validate your P34x the way your generator runs.

Services
Relay Testing, Programming & Configuration

Relay Testing, Programming & Configuration

Coordinated systems for complete generator protection

Complementary protection, control, and communication solutions designed to operate alongside MiCOM P34x, supporting secure synchronism, breaker supervision, and seamless integration across modern power plants and substations.

Upgrade your generator protection

Speak to our engineers to configure, modernise or retrofit MiCOM P34x into your plant.

Get A Quote
Get A Quote
0 Enquiry List